1. DC+: Connect the positive pole of the power supply
2. DC-: connected to the negative pole of the power supply
3. IN1-IN4: According to the setting of each way, the corresponding relay can be controlled by high or low level.
1. NO1--NO4: The relay normally open interface, the relay is suspended before the suction, and it is short-circuited with COM after the suction.
2. COM1--COM4 relay common interface
3. NC1--NC4: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed.
1.> S1-S4 are the high and low level trigger selections of relays 1 to 4 in sequence;
2.> com is shorted with low, the corresponding relay is triggered by low level, and when com is shorted with high terminal, it is triggered by high level.
Relay version: 5v
Quiescent Current: 5mA
Maximum current:190mA
Trigger current: 2-4mA
Low trigger voltage: 0-1.5V
High trigger voltage: 2.5-5V.