SMOKE DETECTOR CONNECTIVITY:SM120X - Interconnect Accessories Smoke Relay Module: 408-SM120X - Smoke Relay Module,Internal power Supply for pull station comparability controls and connects auxiliary warning devices FUNCTIONALITY:This module is only activated by a smoke alarm interconnect signal. The relay portion of this module can be used to activate auxiliary warning devices such as external bells and sirens, hallway or stairwell lighting. It provides isolated, (no internal connection to 120 volts AC) normally open, and normally closed contacts. COMPATIBILITY:This smoke relay module seamlessly connects with Kidde Fyrnetics devices only and most standard smoke detectors, ensuring reliable integration with your existing home safety system.The model SM120X module is for use with the following interconnectable models: Smoke Alarms: 1235, 1235CA, 1275, 1275CA, 1276, 1276CA, 1285, 1285CA, 1296, i12020, i12020CA, i12040, i1240CA, i12060, i12060CA, i12080, PE120, PE120CA, PI2000, and PI2000CA, RF-SM-ACDC, CO/ Smoke Combo alarms: KN-COSM-IB and KN-COSM-IBCA, and Heat Alarms, HD135F, and HD135FCA, all with red interconnect wires. EASE OF USE: Switches connected device power when a smoke/heat interconnect signal is received.Each module is equivalent to one interconnect alarm, reduce the maximum number of interconnect devices by one for each module used. Do not exceed the total number of devices allowable in the interconnect system, refer to the individual alarm owners manual for the maximum number of units allowed when interconnecting. Do not exceed the temperature or humidity limits of +40°F (4.4°C) to 100°F (37.8°C) (such as in garages and unfinished attics) and 90% relative humidity for either the relay module or the alarms. USAGE SPECIFICATIONS:408-Sm120x ,Includes: 10 in. Long 18 GA pigtail leads. -Test/reset button. Power Supply portion can be used with manual pull stations, flow switches and spot type heat detectors. Use with interconnected installations. power source: 120 VAC, 60 Hz, .08 amp. CUSTOMER SUPPORT: At Pokin, we are committed to your satisfaction. If you have any questions or concerns about our smoke relay module, please contact us via Amazon. Our dedicated support team is here to ensure you have a seamless shopping experience and are completely satisfied with your purchase.
Product manual
SM120X Interconnect Accessories Smoke Relay Module
Compatible Brands: for K idde
Model:SM120X
Sensor type: relay module
Product type: SecuritySystem Accessories
power source: 120 VAC, 60 Hz, .08 amp
Includes: 10 in. Long 18 GA pigtail leads
Switches connected device power when a smoke/heat interconnect signal is received
Internal power Supply for pull station comparability controls and connects auxiliary warning devices
Used with multiple station alarms and detectors use with K idde fyrnetics devices only
Kidde SM120X Interconnect Accessories Smoke Relay Module 408-SM120X Smoke Relay Module
Install
Most alarm systems, even wireless alarm systems, can monitor one or two hard wired alarms, whether it's smoke detector relays like this or window alarms. Some people hope that the wired alarm is a normally closed circuit, while others hope that it is a normally open circuit, and this relay module has outputs from both. Need to clarify what your alarm system expects and how many 'termination resistors' it requires (if any). You only need to purchase the resistor (if needed) at Radio Shack, choose the appropriate lead according to your alarm manual and relay module manual, and then easily connect everything together. Your alarm system manual may have a clear chart. You can connect it to any smoke detector box, so just choose the most convenient location for your alarm system.