High quality portable canine progesterone analyzer. The test result value is relatively small. Because it is different from the reference value of the local American testing machine. We have proven that the test results of this machine range from 15 to 25, which is suitable for animal breeding. Determine the optimal breeding time accurately by assessing progesterone levels in the bitch's sample, achieving a precision rate exceeding 96%. This capability ensures successful mating and pregnancy outcomes. Model: YF-YT8A. Dimensions: 210 x 175 x 75 millimeters. Weight: 1 kilogram. Power supply: 100-240VAC, 50/60Hz, 12VDC. Working environment: Temperature: 5 ℃ -40 ℃, humidity: 10-70%. The test strip card that comes with the analyzer must be used. Before using the analyzer, please read the manual carefully. Strictly follow the operating steps in the manual to avoid affecting the accuracy of the test results. Package 3 includes: 1 x Progesterone Detector, 6 x Nitrile Gloves, 1 x Backup system card, 100 x Test Card, 1 x Bandage,1 Set Pipette, 1000 pcs Pipette tip, 1set Centrifuge, 500pcs Centrifuge tube, 100 pcs Canine Insemination Catheter. Progesterone Operation Precautions and Data Reference: 1. Draw blood, at least 2-3 ml of venous blood. Too little may cause poor serum centrifugation. 2. Centrifuge, 4000 rpm for 15 minutes, if the separation is not very good, you can continue for five minutes. 3. The serum pipette must be quantified to 80ul. 4. When the pipette is used to extract serum, be sure to press the first gear, and the position with the handle should not be pressed to the end. 5. Drop the serum into the round hole reagent card, wait for the serum to flow into the strip detection area, insert the round hole upwards and forwards into the instrument card slot, and click the test on the machine to enter the self-test mode. 6. Operating environment temperature must be above 22 degrees. 7. If more than two dogs are detected at the same time, the blood can be labeled and the serum is separated at the same time. Add the serum to each reagent card. The first reagent card is inserted into the instrument card slot, and click the test, the instrument automatically enters fifteen minutes of detection mode, at the same time the other reagent cards are simultaneously reacted for 15 minutes in the external environment. After the first reagent is output, switch the instrument to the instant test mode, and insert the other reagent cards into the machine to read the results. The 15-minute test results will prevail.