Safety protection: The industrial generator GFCI is a safety device specially designed to protect personnel and equipment in industrial environments from electric shock and current leakage hazards High performance: This GFCI has higher current and voltage tolerance, and can adapt to the high power output and voltage fluctuations of industrial generators Quick response: When a ground fault is detected, it can cut off the circuit within milliseconds, effectively preventing potential electric shock accidents Anti-interference design: Common electromagnetic interference and voltage fluctuations in industrial environments will not affect the normal operation of this industrial-grade GFCI, ensuring stable and reliable protection Wide range of application: This generator leakage protector is suitable for various industrial scenarios, such as construction sites, outdoor activities, emergency power supply and industrial production sites where generators are needed This GFCI outlet has a tamper-resistant outlet function, which protects children from electric shock by preventing objects from being inserted into the outlet slot, providing a safe choice for you and your family The industrial generator GFCI (Ground Fault Circuit Interrupter) is a safety protection device designed specifically for industrial generators. It can prevent electric shock, reduce the risk of fire, and protect equipment from current leakage. The generator GFCI can adapt to the voltage and current characteristics of the generator, has strong anti-interference ability, fast response speed, and high reliability. It is widely used in construction sites, outdoor activities, emergency power supply, and industrial production sites. It can improve the safety of the working environment and protect expensive industrial equipment. It has higher current and voltage tolerance, stronger anti-interference ability, and is specially designed for the fluctuation characteristics of the generator. It is an important equipment to ensure the safe operation of industrial generators and can effectively prevent electric shock accidents and equipment damage. Specification:
Grounding: Standard Grounding Rated Voltage: 120V Rated Current: 15A/20A Trip at 5 mA (士1mA) threshold Trip in 0.025 seconds for 240mA fault Application: Residential/General-Purpose Electrical Characteristics: AC120V/15A/20A Unloaded plug≥5000Sec Loop detection with automatic monitoring function Meet the standard:UL,CUL Housing material flame retardant grades Tripping threshold:5mA Tripping time<25ms Surge current:6000V/3000A 6000V/10KA Electric strength:Pressure resistance1500V 50Hz Duration 1Min Insulation resistance:>50MΩ(DC500V) Short-circuit current:10KA Insert and Draw Frequency>10000 times Temperature,humidity:-35℃ ~ +66℃; 20% ~ 90% Storage Temperature,Humidity: -20℃ ~ +85℃; 10% ~ 95%RH